How to check an EICR is valid
You check the date on an EICR and stop. The report says more than that, in three places most landlords never read, and a certificate that fails any of them is worth less than the paper it sits on.
Last reviewed 20 August 2026 · England
An EICR arrives, you file it, and the box in your head marked “electrics” goes from red to green. The date on the front tells you when to look at it again. It does not tell you whether the report is any good, and a landlord who never checks the other three things can hold a document that looks complete and protects nobody.
The three checks beyond the date
A valid EICR for a rental property in England needs all three of these, not one.
- The electrician who signed it holds current registration with a competent person scheme.
- The report is marked satisfactory, or every C1 and C2 code it lists has been fixed and re-tested.
- You are working to the re-inspection date the report actually sets, not the five-year default.
Checking the electrician, not just the signature
Anyone can print a name at the bottom of a document. What makes an EICR count is the electrician’s registration with a competent person scheme, most commonly NICEIC, NAPIT or ELECSA. Each scheme runs a free public register where you enter a registration number and confirm it is current. Check that before you accept the report, the same way you would check a gas engineer against the Gas Safe Register. An unregistered electrician can still hand you a document with all the right boxes ticked. It is not evidence of a real inspection, and a council treats it the same as no certificate at all.
Reading the classification codes
An EICR grades every observation it makes with a code. Read past the summary page and check what each one actually means for the property.
| Code | What it means |
|---|---|
| C1 | Danger present. Immediate risk of injury, and the fault needs fixing before the report can even be called satisfactory. |
| C2 | Potentially dangerous. Not an emergency, but urgent, and a landlord who ignores it holds no defence if it causes harm later. |
| C3 | Improvement recommended. Does not stop the report being satisfactory, but it is on record and worth acting on. |
| FI | Further investigation required. The report is not finished until that investigation happens. |
A report carrying an unresolved C1 or C2 is unsatisfactory, whatever the covering letter says. Landlords who read only the first page of a long EICR sometimes miss this, because the codes sit in a table further down, next to observations that read like an electrician’s shorthand rather than a verdict.
The date that actually decides
An EICR defaults to five years. That default only holds if the electrician did not set a shorter re-inspection interval, which they can and do for ageing wiring or a heavily used installation. When they do, the date printed inside the report is the one that counts, not the five-year mark, a distinction covered in full in EICR rules for rental properties. A landlord checking only the certificate’s issue date and adding five years can be months, or years, past the real deadline without knowing it.
Why an invalid EICR is worse than no EICR
A landlord with no certificate at least knows where they stand. A landlord holding one that fails a registration check, carries an unresolved C1 or C2, or runs to the wrong date believes the property is covered and finds out otherwise during a council inspection or a tenant dispute, not before one. The reasonable steps defence only holds up if what you produce actually stands up to a second look, and electrical safety carries the largest civil penalty on a landlord’s checklist in England, up to £40,000 per offence under the Renters’ Rights Act.
What to do now
- Pull out your current EICR and find the electrician’s registration number.
- Check that number against NICEIC, NAPIT or ELECSA’s public register.
- Read past the summary and check for any unresolved C1 or C2 code.
- Find the re-inspection date printed inside the report, not the issue date plus five years.
- Keep the certificate and that date somewhere you will actually check again. CertSorted holds it alongside every other certificate on one screen and reminds you at 90, 60, 30 and 7 days before the date runs out.